Piezometer - DWLR System

Discover the strength and durability of our Piezometer - DWLR System, a trending solution trusted by service providers, manufacturers, and suppliers across India, benefiting from our over 8 years of experience in this field. Featuring our top models-PM20, PM21, PM22, and PM23 Piezometer DWLR Systems-these products are engineered for instant savings, reliable performance, and unmatched accuracy in groundwater and borewell water level monitoring. With unmatchable data precision, marvelous easy-to-use interface, high resistance to harsh environmental conditions, unparalleled long-term operational stability, and seamless integration into existing infrastructure, our Piezometer - DWLR System sets the industry benchmark. Order today to enjoy the most robust application performance and ensure the highest levels of water management efficiency in your projects, capitalizing on supply ability across All India for rapid fulfillment.

PM20 Piezometer DWLR System

MOQ : 1 Unit

  • Equipment Type
  • Piezometer DWLR (Digital Water Level Recorder) System
  • Accuracy
  • 0.1% F.S.
  • Application Media
  • Water / Groundwater
  • Axis Type
  • Single axis (depth)
  • Capacity
  • Data logger capacity 40,000 readings
  • Color
  • White & Blue (unit), Black (cable)
  • Connecting Type
  • Cable with sealed connector
  • Connectivity Type
  • Cable, RS232/RS485
  • Connector
  • IP68 waterproof
  • Current Range
  • 4-20 mA (optional)
  • Diameter
  • 25 mm (sensor)
  • Dimension (L*W*H)
  • 150 mm x 100 mm x 50 mm (electronics unit)
  • Display Type
  • Other, Digital Display with Data Logger Option
  • Frequency
  • Data logging: programmable interval
  • Housing Material
  • Polycarbonate (electronics), Stainless Steel (sensor)
  • Humidity %
  • 0 to 95% RH non-condensing
  • Input
  • 12V DC
  • Language
  • English
  • Length
  • Standard 50 m cable, extendable up to 100 m
  • Material
  • Stainless Steel (sensor), Polycarbonate (unit housing)
  • Measurement Range
  • 0-100 meters water column
  • Measuring Units
  • meters, centimeters, feet
  • Model
  • PM20
  • Mounting
  • Direct to well casing / pit
  • Operating Temperature
  • -10C to 60C
  • Output
  • RS232/RS485 Serial, Analog 4-20mA (optional)
  • Power Consumption
  • <5 W
  • Power Supply
  • 12V DC Adapter / Battery
  • Pressure Range
  • 0-10 bar
  • Process Connection
  • Gland Sealed Cable Entry
  • Protection
  • IP68 (sensor), Weatherproof Enclosure (electronics)
  • Range
  • 0-100 meters water column
  • Resolution
  • 1 mm
  • Response Time
  • <1 second
  • Sensitivity
  • 0.1% F.S.
  • Sensor Type
  • Vented/Atmospheric Reference Type
  • Signal Type
  • Digital & Analog
  • Stability
  • 0.05% F.S./year
  • Storage Temperature
  • -20C to 70C
  • Temperature Range
  • -10C to 60C

PM21 Piezometer DWLR System

MOQ : 1 Unit

  • Equipment Type
  • Piezometer DWLR (Digital Water Level Recorder) System
  • Accuracy
  • 0.05% FS
  • Application Media
  • Water Level Monitoring
  • Axis Type
  • Single (vertical)
  • Capacity
  • Data Logger Storage up to 20,000 readings
  • Color
  • White (logger), Black (cable)
  • Connecting Type
  • Plug with cable (sensor side); Terminal block (logger)
  • Connectivity Type
  • Wired, RS232/RS485
  • Connector
  • Waterproof Connector
  • Current Range
  • 4-20mA
  • Diameter
  • Approx. 22 mm (Sensor)
  • Dimension (L*W*H)
  • Logger Box approx. 150x100x50 mm
  • Display Type
  • Other, Digital Display with Data Logger
  • Frequency
  • Data Log Frequency Configurable (1 sec to 1 hr)
  • Housing Material
  • Stainless Steel (sensor), ABS/Polycarbonate (logger)
  • Humidity %
  • 0-95% RH (non-condensing)
  • Input
  • Submersible Hydrostatic Sensor
  • Language
  • English
  • Length
  • Cable length customizable (up to 100m)
  • Load Capacity
  • Designed for submerged operation
  • Material
  • Stainless Steel Sensor; Polycarbonate Logger Casing
  • Measurement Range
  • 0-100m
  • Measuring Units
  • Meters, Centimeters
  • Model
  • PM21
  • Mounting
  • Wall or Surface Mount Logger; Submersible Sensor
  • Operating Temperature
  • -10C to 60C
  • Output
  • RS232/RS485, Data Logger Storage
  • Power Consumption
  • Low (typically <5W)
  • Power Supply
  • 12V DC Adapter
  • Pressure Range
  • 0-10 bar
  • Process Connection
  • Customized Cable Length
  • Protection
  • IP68 (Sensor) / IP65 (Logger)
  • Range
  • 0-100m (Customizable)
  • Resolution
  • 1 mm
  • Response Time
  • <2 seconds
  • Sensitivity
  • High
  • Sensor Type
  • Hydrostatic, Submersible
  • Signal Type
  • Digital
  • Stability
  • 0.02% FS/year
  • Storage Temperature
  • -20C to 85C
  • Temperature Range
  • -10C to 60C

PM22 Piezometer DWLR System

MOQ : 1 Unit

  • Equipment Type
  • Digital Water Level Recorder (DWLR)
  • Accuracy
  • 0.1% FS
  • Application Media
  • Water Level Monitoring
  • Axis Type
  • Single Axis (Vertical)
  • Capacity
  • Data storage for >12 months
  • Color
  • White
  • Connecting Type
  • Wired
  • Connectivity Type
  • RS232/RS485
  • Connector
  • Terminal Block
  • Current Range
  • 4-20 mA
  • Diameter
  • Standard 48 mm
  • Dimension (L*W*H)
  • 180mm x 120mm x 90mm
  • Display Type
  • Other, Digital LCD
  • Housing Material
  • ABS/Plastic
  • Humidity %
  • 95% RH (Non-condensing)
  • Input
  • Sensor Input (Pressure Transducer)
  • Language
  • English (Default)
  • Length
  • Cable length as per site requirement
  • Load Capacity
  • NA for electronics module
  • Material
  • Industrial Grade Plastic/ABS
  • Measurement Range
  • 0-100 meters
  • Measuring Units
  • Meters, Feet
  • Model
  • PM22 Piezometer DWLR System
  • Mounting
  • Wall Mounted/Panel Mounted
  • Operating Temperature
  • -10C to +60C
  • Output
  • Digital Data Output
  • Power Consumption
  • Low (< 5W)
  • Power Supply
  • 230V AC / 12V DC
  • Pressure Range
  • Up to 10 bar
  • Process Connection
  • Direct Well/Bore Installation
  • Protection
  • IP65 Enclosure
  • Range
  • 0-100 meters
  • Resolution
  • 1 mm
  • Response Time
  • < 1 second
  • Sensitivity
  • High Sensitivity
  • Sensor Type
  • Vented Pressure Transducer (Piezoelectric)
  • Signal Type
  • RS232/RS485
  • Stability
  • High Stability
  • Storage Temperature
  • -20C to +70C
  • Temperature Range
  • -10C to +60C

PM23 Piezometer DWLR System

MOQ : 1 Unit

  • Equipment Type
  • Digital Water Level Recorder (DWLR)
  • Acceleration Range
  • --
  • Accuracy
  • High accuracy digital measurement
  • Application Media
  • Water, Groundwater
  • Axis Type
  • Single channel measurement
  • Capacity
  • Data storage for up to 50,000 readings (expandable)
  • Color
  • White
  • Connecting Type
  • Cable gland / terminal block
  • Connectivity Type
  • GPRS/SMS, USB for data download
  • Connector
  • Industrial grade terminal blocks
  • Current Range
  • 4-20 mA for sensor (optional)
  • Cut Size
  • Standard for enclosure
  • Diameter
  • Sensor diameter typically 25 mm / Custom sizes available
  • Dimension (L*W*H)
  • 220mm x 150mm x 100mm
  • Display Type
  • Other, LCD Alphanumeric
  • Flow Rate
  • --
  • Frequency
  • User settable data logging interval
  • Housing Material
  • ABS/Polycarbonate
  • Humidity %
  • 0-100% RH (non-condensing)
  • Input
  • Sensor (submersible/pressure transducer)
  • Language
  • English
  • Length
  • Standard cable lengths available
  • Load Capacity
  • --
  • Material
  • ABS Engineering Plastic
  • Measurement Range
  • upto 100 meters (water level)
  • Measuring Units
  • Meters / Feet
  • Microphone
  • --
  • Model
  • PM23 Piezometer DWLR System
  • Mounting
  • Wall/Panel Mount
  • Operating Temperature
  • -10C to +60C
  • Output
  • Digital; GPRS/SMS/Cloud/SCADA compatible
  • Power Consumption
  • Low power consumption (designed for field applications)
  • Power Supply
  • 12V DC
  • Pressure Range
  • 0-10 bar (for sensor)
  • Process Connection
  • Through piezometer well head
  • Protection
  • Weatherproof enclosure
  • Range
  • 0-100 meters (other ranges available on request)
  • Resolution
  • 1 mm
  • Response Time
  • Instantaneous (real-time recording)
  • Sensitivity
  • High sensitivity for low water level changes
  • Sensor Type
  • Water Level Sensor (Piezometric)
  • Signal Type
  • Digital and Analog
  • Stability
  • Long-term zero and span stability
  • Storage Temperature
  • -20C to +60C
  • Temperature Range
  • -10C to +60C
  • Velocity Range
  • --
  • Wind Speed
  • --


Back to top